Well, I decided the cool thing to do was to port the test software directly to the Pi in python and run it there. I approached this with a little trepidation; taking things from an Arduino to another platform and language can drive you nuts. First, I already have an XBee attached to the Pi; it uses the (only) serial port on the little device, so I got a Sparkfun XBee explorer <link> and plugged it into the USB port. Fully expecting to have to jump through a bunch of hoops to get it to work, I did a simple 'cat /dev/ttyUSB0' command and actually got output to the screen on the very first try!
Sure it was garbage and didn't mean much, but I got output that corresponded to pushing the button on the switch. Step one was done. Next I put together a little code using the python XBee library to catch a packet and see what happened. Right off the bat, I got this printed on the console of the Pi:
{'profile': '\xc2\x16', 'source_addr': '+\xd1', 'dest_endpoint': '\x02', 'rf_data': '\t\x00\x81T\x00', 'source_endpoint': '\x02', 'options': '\x01', 'source_addr_long': '\x00\ro\x00\x027\xb2Z', 'cluster': '\x00\xef', 'id': 'rx_explicit'}
The Python Script
#! /usr/bin/python # This is the an implementation of controlling the Lowe's Iris Smart # Switch. It will join with a switch and allow you to control the switch # # Only ONE switch though. This implementation is a direct port of the # work I did for an Arduino and illustrates what needs to be done for the # basic operation of the switch. If you want more than one switch, you can # adapt this code, or use the ideas in it to make your own control software. # # Have fun from xbee import ZigBee from apscheduler.scheduler import Scheduler import logging import datetime import time import serial import sys import shlex #------------------------------------------------- # the database where I'm storing stuff DATABASE='/home/pi/database/desert-home' # on the Raspberry Pi the serial port is ttyAMA0 XBEEPORT = '/dev/ttyUSB0' XBEEBAUD_RATE = 9600 # The XBee addresses I'm dealing with BROADCAST = '\x00\x00\x00\x00\x00\x00\xff\xff' UNKNOWN = '\xff\xfe' # This is the 'I don't know' 16 bit address switchLongAddr = '12' switchShortAddr = '12' #------------------------------------------------- logging.basicConfig() #------------ XBee Stuff ------------------------- # Open serial port for use by the XBee ser = serial.Serial(XBEEPORT, XBEEBAUD_RATE) # this is a call back function. When a message # comes in this function will get the data def messageReceived(data): # print 'gotta packet' # print data # This is a test program, so use global variables and # save the addresses so they can be used later global switchLongAddr global switchShortAddr switchLongAddr = data['source_addr_long'] switchShortAddr = data['source_addr'] clusterId = (ord(data['cluster'][0])*256) + ord(data['cluster'][1]) print 'Cluster ID:', hex(clusterId), if (clusterId == 0x13): # This is the device announce message. # due to timing problems with the switch itself, I don't # respond to this message, I save the response for later after the # Match Descriptor request comes in. You'll see it down below. # if you want to see the data that came in with this message, just # uncomment the 'print data' comment up above print 'Device Announce Message' elif (clusterId == 0x8005): # this is the Active Endpoint Response This message tells you # what the device can do, but it isn't constructed correctly to match # what the switch can do according to the spec. This is another # message that gets it's response after I receive the Match Descriptor print 'Active Endpoint Response' elif (clusterId == 0x0006): # Match Descriptor Request; this is the point where I finally # respond to the switch. Several messages are sent to cause the # switch to join with the controller at a network level and to cause # it to regard this controller as valid. # # First the Active Endpoint Request payload1 = '\x00\x00' zb.send('tx_explicit', dest_addr_long = switchLongAddr, dest_addr = switchShortAddr, src_endpoint = '\x00', dest_endpoint = '\x00', cluster = '\x00\x05', profile = '\x00\x00', data = payload1 ) print 'sent Active Endpoint' # Now the Match Descriptor Response payload2 = '\x00\x00\x00\x00\x01\x02' zb.send('tx_explicit', dest_addr_long = switchLongAddr, dest_addr = switchShortAddr, src_endpoint = '\x00', dest_endpoint = '\x00', cluster = '\x80\x06', profile = '\x00\x00', data = payload2 ) print 'Sent Match Descriptor' # Now there are two messages directed at the hardware # code (rather than the network code. The switch has to # receive both of these to stay joined. payload3 = '\x11\x01\x01' zb.send('tx_explicit', dest_addr_long = switchLongAddr, dest_addr = switchShortAddr, src_endpoint = '\x00', dest_endpoint = '\x02', cluster = '\x00\xf6', profile = '\xc2\x16', data = payload2 ) payload4 = '\x19\x01\xfa\x00\x01' zb.send('tx_explicit', dest_addr_long = switchLongAddr, dest_addr = switchShortAddr, src_endpoint = '\x00', dest_endpoint = '\x02', cluster = '\x00\xf0', profile = '\xc2\x16', data = payload4 ) print 'Sent hardware join messages' elif (clusterId == 0xef): clusterCmd = ord(data['rf_data'][2]) if (clusterCmd == 0x81): print 'Instantaneous Power', print ord(data['rf_data'][3]) + (ord(data['rf_data'][4]) * 256) elif (clusterCmd == 0x82): print "Minute Stats:", print 'Usage, ', usage = (ord(data['rf_data'][3]) + (ord(data['rf_data'][4]) * 256) + (ord(data['rf_data'][5]) * 256 * 256) + (ord(data['rf_data'][6]) * 256 * 256 * 256) ) print usage, 'Watt Seconds ', print 'Up Time,', upTime = (ord(data['rf_data'][7]) + (ord(data['rf_data'][8]) * 256) + (ord(data['rf_data'][9]) * 256 * 256) + (ord(data['rf_data'][10]) * 256 * 256 * 256) ) print upTime, 'Seconds' elif (clusterId == 0xf0): clusterCmd = ord(data['rf_data'][2]) print "Cluster Cmd:", hex(clusterCmd), if (clusterCmd == 0xfb): print "Temperature ??" else: print "Unimplemented" elif (clusterId == 0xf6): clusterCmd = ord(data['rf_data'][2]) if (clusterCmd == 0xfd): print "RSSI value:", ord(data['rf_data'][3]) elif (clusterCmd == 0xfe): print "Version Information" else: print data['rf_data'] elif (clusterId == 0xee): clusterCmd = ord(data['rf_data'][2]) if (clusterCmd == 0x80): print "Switch is:", if (ord(data['rf_data'][3]) & 0x01): print "ON" else: print "OFF" else: print "Unimplemented Cluster ID", hex(clusterId) print def sendSwitch(whereLong, whereShort, srcEndpoint, destEndpoint, clusterId, profileId, clusterCmd, databytes): payload = '\x11\x00' + clusterCmd + databytes # print 'payload', # for c in payload: # print hex(ord(c)), # print # print 'long address:', # for c in whereLong: # print hex(ord(c)), # print zb.send('tx_explicit', dest_addr_long = whereLong, dest_addr = whereShort, src_endpoint = srcEndpoint, dest_endpoint = destEndpoint, cluster = clusterId, profile = profileId, data = payload ) #------------------If you want to schedule something to happen ----- #scheditem = Scheduler() #scheditem.start() #scheditem.add_interval_job(something, seconds=sometime) #----------------------------------------------------------------- # Create XBee library API object, which spawns a new thread zb = ZigBee(ser, callback=messageReceived) print "started at ", time.strftime("%A, %B, %d at %H:%M:%S") print "Enter a number from 0 through 8 to send a command" while True: try: time.sleep(0.001) str1 = raw_input("") # Turn Switch Off if(str1[0] == '0'): print 'Turn switch off' databytes1 = '\x01' databytesOff = '\x00\x01' sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xee', '\xc2\x16', '\x01', databytes1) sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xee', '\xc2\x16', '\x02', databytesOff) # Turn Switch On if(str1[0] == '1'): print 'Turn switch on' databytes1 = '\x01' databytesOn = '\x01\x01' sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xee', '\xc2\x16', '\x01', databytes1) sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xee', '\xc2\x16', '\x02', databytesOn) # this goes down to the test routine for further hacking elif (str1[0] == '2'): #testCommand() print 'Not Implemented' # This will get the Version Data, it's a combination of data and text elif (str1[0] == '3'): print 'Version Data' databytes = '\x00\x01' sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xf6', '\xc2\x16', '\xfc', databytes) # This command causes a message return holding the state of the switch elif (str1[0] == '4'): print 'Switch Status' databytes = '\x01' sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xee', '\xc2\x16', '\x01', databytes) # restore normal mode after one of the mode changess that follow elif (str1[0] == '5'): print 'Restore Normal Mode' databytes = '\x00\x01' sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xf0', '\xc2\x16', '\xfa', databytes) # range test - periodic double blink, no control, sends RSSI, no remote control # remote control works elif (str1[0] == '6'): print 'Range Test' databytes = '\x01\x01' sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xf0', '\xc2\x16', '\xfa', databytes) # locked mode - switch can't be controlled locally, no periodic data elif (str1[0] == '7'): print 'Locked Mode' databytes = '\x02\x01' sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xf0', '\xc2\x16', '\xfa', databytes) # Silent mode, no periodic data, but switch is controllable locally elif (str1[0] == '8'): print 'Silent Mode' databytes = '\x03\x01' sendSwitch(switchLongAddr, switchShortAddr, '\x00', '\x02', '\x00\xf0', '\xc2\x16', '\xfa', databytes) # else: # print 'Unknown Command' except IndexError: print "empty line" except KeyboardInterrupt: print "Keyboard interrupt" break except NameError as e: print "NameError:", print e.message.split("'")[1] except: print "Unexpected error:", sys.exc_info()[0] break print "After the while loop" # halt() must be called before closing the serial # port in order to ensure proper thread shutdown zb.halt() ser.close()
Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Minute Stats: Usage, 60285 Watt Seconds Up Time, 1200 Seconds Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Minute Stats: Usage, 65266 Watt Seconds Up Time, 1260 Seconds Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 84 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Minute Stats: Usage, 70250 Watt Seconds Up Time, 1320 Seconds Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Minute Stats: Usage, 75230 Watt Seconds Up Time, 1380 Seconds Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Minute Stats: Usage, 80213 Watt Seconds Up Time, 1440 Seconds Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Minute Stats: Usage, 85194 Watt Seconds Up Time, 1500 Seconds Cluster ID: 0xef Instantaneous Power 84 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xf0 Cluster Cmd: 0xfb Temperature ?? Cluster ID: 0xef Instantaneous Power 83 Cluster ID: 0xef Instantaneous Power 83
Now I have the basics of reading the switch, and all I have to do now is hook it up with the rest of the software in the House Controller. Then I can place these things wherever I want either, control of the power, or a measurement of how much power is being used. Very nice little switch; I couldn't have built one for the price off the shelf at Lowe's. And most importantly to me, I have control of it, not some cloud server or control device that I have to rely on a corporation's whim to change to fit my needs.
Have fun.